emka TECHNOLOGIES S.A.
59, bd. Général Martial Valin
75015 Paris - France
tel: + 33 (0)1 40 60 76 00
fax: +33 (0)1 40 60 65 55
e-mail: emka@emka.fr
emka TECHNOLOGIES Inc.
307 Annandale Road, suite 203
Falls Church, VA 22042 - USA
tel: +1 (703) 237-9001
fax: +1 (703) 237-9006
e-mail: emkatech@emkatech.com
      site map  
      newsletter
      contact us  
      legal info
  HomeCompanyProductsApplicationsServices
 
emka TECHNOLOGIES' applications for safety pharmacology and toxicology studies
    what you need

  your applications
  s7a & s7b requirements s7a & s7b requirements
  ecg ecg
  ecg - sedated mice ecg - sedated mice
  cardiovascular cardiovascular
  baroreflex sensitivity baroreflex sensitivity
  thrombosis thrombosis
  working heart working heart
  electrophysiology electrophysiology
  cardiac ap cardiac ap
  cardiac conductivity cardiac conductivity
  pulmonary pulmonary
  cigarette exposure cigarette exposure
  cardiorespiratory cardiorespiratory
  gas mixture exposure gas mixture exposure
  recording apneas recording apneas
  hemodynamics hemodynamics
  pv loops pv loops
  minipigs minipigs
  primates primates
  telemetry telemetry
  telemetry in primates telemetry in primates
  telemetry in rodents telemetry in rodents
  telemetry in dogs telemetry in dogs
  telemetry in swine telemetry in swine
  isolated organs isolated organs
  cns studies cns studies
  behavior behavior
  case studies case studies
  arrange a demo arrange a demo
  request a quote request a quote
> home > applications > recording apneas

recording apneas

The setup for whole-body plethysmography with freely moving animals can be used to record apneas by using the appropriate analyzer module in iox2 software (module available as an option). No extra hardware is required.

As a reminder, one signal is measured in this setup: respiratory flow from a differential pressure transducer. An apnea is considered to be a breath with specific characteristics, such as long expiratory time and end-expiratory pause.

apnea analyzer

The apnea analyzer is an add-on module for iox2 software. The respiratory flow signal waveforms go through two processing stages, which together serve to filter out apneas:

  • detect a breath (including apneas).
  • reject "normal" breaths.

Each stage has its own panel with user-adjustable settings. In the rejection settings panel, you provide minimum and maximum values for one or more parameters. For example, you can set the analyzer to reject waveforms with an end-expiratory pause less than than 1 second.

Rejection Settings of Apnea Analyzer (module for iox2 software)  Breath Detection Settings of Apnea Analyzer (module for iox2 software)
settings panels of the apnea analyzer module

The apnea analyzer reports a count of apneas (per period and cumulative total) as well as several flow-derived parameters for these apneas (inspiratory time, expiratory time, peak inspiratory and expiratory flows,…). 
 

Please visit our minisite at pulmonary.emka.fr to find out more about how emka TECHNOLOGIES can help you perform pulmonary studies. The minisite contains further information about our different setups; how to find the right system for your needs; FAQs; literature to download; list of customers and how they are using telemetry; acquired parameters etc.

 



  case studies
CHALLENGE: Some signals are not easy to measure directly either because access is limited&…

> learn more
 
 
 
Rreceive alerts about emka TECHNOLOGIES' facebook page (new products, events, photos…) FACEBOOK Bookmark emka TECHNOLOGIES website for yourself and friends with DEL.ICO.US social bookmarking. DEL.ICO.US Use Digg to promote and share the best content on the web, like from www.emka.fr DIGG subscribe to emka TECHNOLOGIES' rss feed!