emka TECHNOLOGIES S.A.
59, bd. Général Martial Valin
75015 Paris - France
tel: + 33 (0)1 40 60 76 00
fax: +33 (0)1 40 60 65 55
e-mail: emka@emka.fr
emka TECHNOLOGIES Inc.
307 Annandale Road, suite 203
Falls Church, VA 22042 - USA
tel: +1 (703) 237-9001
fax: +1 (703) 237-9006
e-mail: emkatech@emkatech.com
      site map  
      newsletter
      contact us  
      legal info
  HomeCompanyProductsApplicationsServices
 
emka TECHNOLOGIES' applications for safety pharmacology and toxicology studies
    what you need

  your applications
  s7a & s7b requirements s7a & s7b requirements
  ecg ecg
  ecg - sedated mice ecg - sedated mice
  cardiovascular cardiovascular
  baroreflex sensitivity baroreflex sensitivity
  thrombosis thrombosis
  working heart working heart
  electrophysiology electrophysiology
  cardiac ap cardiac ap
  cardiac conductivity cardiac conductivity
  pulmonary pulmonary
  cigarette exposure cigarette exposure
  cardiorespiratory cardiorespiratory
  gas mixture exposure gas mixture exposure
  recording apneas recording apneas
  hemodynamics hemodynamics
  pv loops pv loops
  minipigs minipigs
  primates primates
  telemetry telemetry
  telemetry in primates telemetry in primates
  telemetry in rodents telemetry in rodents
  telemetry in dogs telemetry in dogs
  telemetry in swine telemetry in swine
  isolated organs isolated organs
  cns studies cns studies
  behavior behavior
  case studies case studies
  arrange a demo arrange a demo
  request a quote request a quote
> home > applications > baroreflex sensitivity

baroreflex sensitivity


The baroreflex is the fastest and most powerful mechanism for regulating blood pressure. Indexes of baroreflex sensitivity (brs) are widely used as a prognostic factor in cardiology. For instance, after a myocardial infarction, a depressed baroreflex sensitivity identifies groups at high risk for cardiovascular mortality.

In preclinical research, assessment of baroreflex sensitivity is used to evaluate potential anti-arrhythmic therapies.

Modern computational techniques can provide an index of brs from a blood pressure signal alone. During recording, changes in blood pressure are induced either pharmacologically or physiologically (e.g. change in posture).

The brs setup from emka TECHNOLOGIES uses a sequence technique for assessing brs. It requires only a blood pressure signal. During analysis, the signal is searched for sequences in which a beat-to-beat interval and blood pressure change in the same direction. These sequences are plotted on a graph, and the best-fitted straight line of each sequence is the brs parameter.

 

 

analysis of blood pressure signal
index of baroreflex sensitivity

analysis of blood pressure signal (top figure) provides an index of baroreflex sensitivity (slope of each line, bottom figure)

brs analysis is an add-on option for the blood pressure (bp) analyzer of ecgAUTO. The user has a choice of which parameter to use for the beat-to-beat interval and blood pressure (available options are those most widely used and accepted in the research community). Furthermore, it is possible to fine-tune the analysis by selecting minimum number of beats in a sequence and minimum variation in signal for start of a sequence.



  case studies
CHALLENGE: Some signals are not easy to measure directly either because access is limited&…

> learn more
 
 
 
Rreceive alerts about emka TECHNOLOGIES' facebook page (new products, events, photos…) FACEBOOK Bookmark emka TECHNOLOGIES website for yourself and friends with DEL.ICO.US social bookmarking. DEL.ICO.US Use Digg to promote and share the best content on the web, like from www.emka.fr DIGG subscribe to emka TECHNOLOGIES' rss feed!